Products
UB 20xx – ex-proof ventilator
In potentially explosive environments, the fan extracts hazardous gases safely and quickly. For ventilation in logistics warehouses and for remediation work in contaminated areas. For repair and maintenance work at petrol stations and tank installations, in manholes and tanks. For use in the chemical industry and for fire brigade operations.
The housing made of a robust plastic material dissipates stresses into the ground and thus prevents static charging and dangerous sparking. The housing and motor seals comply with the high protection class IP 55 and provide effective protection against dust and water. Antistatic hoses ensure safe operation.
ATEX: motor/housing: II 2 G Ex db eb IIB T6 Gb, II 2 G Ex IIB T6 Gb, Zone 1+2
Special features in potentially explosive atmospheres
Installation conditions and the different hazardous areas must be observed; only connect the unit to explosion-protected mains sockets; ground antistatic hoses if necessary.
Fans for explosive atmospheres
Fans with ATEX approval may be operated in Zone 1 and 2.
Zone 1 is an area in which a hazardous explosive atmosphere consisting of a mixture of air and flammable gases, vapours or mists is likely to occur in normal operation occasionally. The equipment is approved for substance group IIB. A typical gas for group IIB is ethylene with an ignition energy of 60 - 180 mJ.
Ventilation of shafts
If the existing natural ventilation in shafts and duct systems is not sufficient due to local conditions such as the location of the shafts or their cover properties, additional, technical ventilation measures become necessary. Especially in warm temperatures, when the air in the manhole is cooler than that in the surrounding area, it is often not possible to provide sufficient ventilation. Even temporarily opening manhole covers is not always sufficient for optimal ventilation.
In sewer shafts, for example, foul gases can displace the oxygen in the air and thus lead to unconsciousness among sewer workers. This can be remedied with targeted technical ventilation and powerful fans. The fresh air then reaches the workplace directly and prevents health impairments caused by bad air.
Sufficient technical ventilation is achieved when, for example, an air flow of at least 600m³/h per m² of duct cross-section is achieved in ducts.
Key features
-
Axial ventilator explosion-proof with an air flow rate of 1392m³/h
-
Robust housing made of high-quality plastic
-
Protection class IP55 (effective against dust and water)
-
Low energy consumption
-
Easy transport ensured by practical handle
Product specifications
Air flow
Air pressure
Fan type
Power consumption
Power supply
Rated current
Protection class
Sound level
Hose
Product size (l x w x h)
Net weight
Useful downloads
Heylo catalogue
Related products
Featured insights
The importance of drying out new buildings during the construction phase.
Enquire about this product
Complete your details below and the right person from our expert team will get back to you.
For service and spare parts enquiries please include serial number and product type in the Message field.